Chiltern Connection Products
Order Code: ITY-001133
QtyEx. VAT
1+£POA
Enquire for price

Description

  • Single Workstation Continuous Monitor
    Continuously monitors the path-to-ground integrity of one operator and one ESD worksurface
  • IMPROVED Operator Alarm
    Alarms when the operator unintentionally disconnects from the monitor or the connection between the banana plug and monitor’s jack is intermittent
  • NEW Mat Monitor Switch
    Disables the worksurface monitor circuit when used in areas where there is no ESD worksurface
  • NEW Audible Alarm Adjustment
    Sets the audible alarm volume from loud to louder
  • NEW 19653 Remote Alarm Accessory
    Connect to the Multi-Mount Monitor and place in the operator’s field of view to alert operator of alarms
  • Desco Wave Distortion Technology
    Provides stable continuous monitoring (versus pulsed or intermittent) of the wrist strap’s path-to-ground* and the presence of its 1 megohm safety resistor
  • Park Snap
    Allows the operator to disconnect (and park) a wrist strap when leaving the workstation without creating a false alarm
  • Single-Wire Impedance Design
    Meets ANSI/ESD S20.20 in accordance with ESD TR1.0-01-0
  • 1.2 Volt Operator Test Voltage
    Reduces the risk of electrical overstress (EOS) for the handling of sensitive components
  • <50 Millisecond Alarm Response Time
    Identifies failures and intermittencies that inferior technologies miss
  • Continuous Visual and Audible Alarms
    Illuminates green to indicate proper grounding; illuminates red and sounds audible alarm when intermittent or failed connection occurs
  • Calibration Verification
    Use the Desco 98221 Verification Tester Unit to check the test limits of Wave Distortion Monitors without removing them from their workstations
  • NIST Calibrated with Certificate Included
    Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology. For more information on the calibration of Desco products, see Calibration.
  • 100-240VAC Power Adapter with IEC C14 Style Inlet
    Connects to a power cord with a IEC C13 outlet connector
  • Made in the United States of America
  • Note: power cord not included
    Choose from 200220 (Europe) or 200225 (UK/Asia)

 

*The ESDA Wrist Strap standard is ANSI/ESD S1.1. The Wrist Strap System required limit per ANSI/ESD S20.20 Table 3 is 0.8 to 1.2 x 106 ohms with product qualification testing per ANSI/ESD S1.1. The test range of the monitored circuit is 500 kilohms to 10 megohms.

Desco Europe - Wave Distortion Technology Demonstration

https://www.youtube.com/watch?v=HnsE6nyYa7M
Downloadables

Brochures

Logo 

Manufacturer: Desco Europe

MPN: 19652

Need Help?

Do you need product exported outside of the UK? 
Or need help with product selection?

Click here to complete our enquiry form and a member of our technical team will be more than happy to help.

Enquiries

Or talk to us today on Live Chat below.

Payment Options

Payment can be made online by debit/credit card or you can request a pro-forma invoice to pay by BACS. (Please note, there are no card fees for online transactions).

If you would like to open a 30 Day Credit Account, complete our Credit Account Form here

On approval of your account, our accounts team will provide you with all the information you require to place your orders.